EasyManua.ls Logo

Telit Wireless Solutions LE910C series - AT#PADFWD - PAD Forward Character

Telit Wireless Solutions LE910C series
1904 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1268 of 1904 2022-03-04
Not Subject to NDA
3.17.20. AT#PADFWD - PAD Forward Character
PAD forward character
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Auto
No
-
2
AT#PADFWD=<char>[,<mode>]
Set command sets the char that immediately flushes pending data to
socket opened by AT#SD command
Parameters:
Name
Type
Default
Description
<char>
integer
1
specifies the ascii code of the char used to
flush data
Value:
0÷255
:
ascii code of the char used to flush data
<mode>
integer
0
flush mode
Values:
0
:
normal mode
1
:
reserved
Use AT#PADCMD to enable the socket char-flush activity
AT#PADFWD?
Read command reports the currently selected <char> and <mode> in the
format:
#PADFWD: <char>,<mode>

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Related product manuals