LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1032 of 1904 2022-03-04
Not Subject to NDA
3.12.6.3. AT#DVICLK - Digital Voiceband Interface Clock
The command configures the DVI clock signal.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Auto
No
-
2
AT#DVICLK=<clock>[,<samplerate>]
Set command configures and activates the DVICLK clock signal and the
Digital Voiceband Interface.
Parameters:
Name
Type
Default
Description
<clock>
integer
0
DVI Clock
Values:
0
:
Disable (factory default)
128
:
DVI Clock activated at 128 KHz
256
:
DVI Clock activated at 256 KHz
512
:
DVI Clock activated at 512 KHz
1024
:
DVI Clock activated at 1024 KHz
2048
:
DVI Clock activated at 2048 KHz
4096
:
DVI Clock activated at 4096 KHz
<samplerate>
integer
0
sample rate
Values:
0
:
audio scheduler sample rate 8KHz
1
:
audio scheduler sample rate 16KHz

Table of Contents