LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 806 of 1904 2022-03-04
Not Subject to NDA
3.9.15. AT#MSCLASS - Multislot Class Control
Set command sets the GPRS multislot class.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Auto
No
-
2
AT#MSCLASS=[<class>[,<autoattach>]]
Parameters:
Name
Type
Default
Description
<class>
integer
33
GPRS multislot class.
Values:
1÷12
:
class
30÷33
:
class
<autoattach>
integer
0
specify when the new
multislot class will be
enabled.
Values:
0
:
the new multislot class is enabled only at the
next detach/attach or after a reboot.
1
:
the new multislot class is enabled immediately,
automatically forcing a detach / attach procedure
only in case of GSM network registered
It is only available for variants that support GSM.
AT#MSCLASS?