3.35.20. AT#BADVINTMAX - BLE Maximum Advertising Interval
This command is used to configure the maximum advertisement interval.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT#BADVINTMAX=<Maximum Advertising Interval>
Set command is used to configure the maximum advertisement interval
for a Bluetooth Low Energy peripheral.
Parameter:
Name
Type
Default
Description
<Maximum
Advertising
Interval>
integer
N/A
It specifies maximum interval used
for advertising (in milliseconds) in
a Bluetooth Low Energy peripheral.
Value:
20÷10240
:
The supported parameter value
range. This value can be saved into
profile through AT#W command.
AT#BADVINTMAX?
Read command is used to get the status of the maximum advertising
interval:
#BADVINTMAX: <Maximum Advertising Interval>
Where,
<Maximum Advertising Interval> - Specifies the maximum advertising
interval. For example:
AT#BADVINTMAX?
#BADVINTMAX: 200
OK