LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1582 of 1904 2022-03-04
3.25.7. AT#DWCONN - Connect to IoT Portal
This command connects/disconnects to the IoT Portal.
AT#DWCONN=<connect>
Set command connects/disconnects to the M2M Service.
Parameter:
flag to connect/disconnect to the M2M
Service
AT#DWCONN=1 performs the socket connection and the MQTT
connection. AT#DWCONN=0 performs the socket disconnection.
the PDP Context used for the network connection is the first
(<cid>=1 has to be previously defined with AT+CGDCONT command
and activated with AT#SGACT command)
if the secure mode connection has been enabled, it cannot be used
contemporarily to any command starting an SSL connection
(including SSL sockets, FTPS, secure SMTP and HTPS).