EasyManuals Logo

Telit Wireless Solutions LE910C series At Commands Reference Guide

Telit Wireless Solutions LE910C series
1904 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #750 background imageLoading...
Page #750 background image
LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 750 of 1904 2022-03-04
Not Subject to NDA
3.8.23. AT#WLANCLOCK - Set SDIO clock of the WLAN
This command is used to set the SDIO clock of the WLAN interface
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#WLANCLOCK=<clock>
Set command for configure SDIO clock of the WLAN.
Parameter:
Name
Type
Default
Description
<clock>
integer
6
parameter to specify the SDIO clock
Values:
1
:
400khz
2
:
20Mhz
3
:
25Mhz
4
:
50Mhz
5
:
100Mhz
6
:
200Mhz
In order to apply new configuration, the WLAN must be restarted.
This value stored into module storage and keep maintain changed
value by customer even if reboot or FW update
AT#WLANCLOCK?
Read currently configured SDIO clock of the WLAN as below format

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals