LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1080 of 1904 2022-03-04
Not Subject to NDA
Power Down
3.14.1. AT#REBOOT - Module Reboot
Immediate module reboot.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT#REBOOT
Execution command reboots immediately the unit.
It can be used to reboot the system after a remote update of the script in
order to have the new one running.
If #REBOOT follows an AT command that stores some
parameters in NVM, it is recommended to insert a delay of at
least 5 seconds before to issue #REBOOT, to permit the complete
NVM storing.
#REBOOT is an obsolete AT command; please refer to #ENHRST
to perform a module reboot.
URC messages occurred during the shutdown procedure of
#REBOOT may not be shown.
AT#REBOOT=?
Test command returns OK result code.
•
Reboot the module
AT#REBOOT
OK
(the module reboots)

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals