LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1584 of 1904 2022-03-04
Not Subject to NDA
3.25.8. AT#DWRCVR - Receive Raw Data from M2M Service
This command permits the user to read raw data arriving from M2M Service.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#DWRCVR=<msgId>
Execution command permits the user to read raw data arriving from M2M
Service; the module is notified of these data by the URC #DWRING.
Parameter:
Name
Type
Default
Description
<msgId>
integer
-
index of the data message to receive, as
indicated in the URC #DWRING
Additional info:
If the data received are the consequence of a previous data sending
(issued by AT#DWSENDR), then the <msgId> value is the same of
the <msgId> value reported in the answer of AT#DWSENDR.
The incoming Server data are notified by the URC #DWRING with
the following format:
#DWRING: <type>,<msgId>,<len>
Name
Type
Default
Description
<type>
integer
-
type of the data message to receive
<msgId>
integer
-
index of the data message to receive

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals