LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 274 of 1904 2022-03-04
3.2.3.10. ATS12 - Escape Prompt Delay
The command manages the prompt delay between two different escape characters.
ATS12=<time>
Set command sets:
8. the minimum period, before receipt of the first character of the
three escape character sequence, during which no other character
has to be detected in order to accept it as valid first character;
9. the maximum period allowed between receipt of first or second
character of the three escape character sequence and receipt of
the next;
10. the minimum period, after receipt of the last character of the three
escape character sequence, during which no other character has to
be detected in order to accept the escape sequence as a valid one.
Parameter:
delay expressed in fiftieth of a second
expressed in fiftieth of a second (0.4 – 3 [s])
The minimum period S12 has to pass after CONNECT result code
too, before a received character is accepted as valid first character
of the three escape character sequence.
If the Escape Sequence Guard Time set to a value different from
zero, it overrides the one set with S12.