3.20.3. AT#HTTPRCV - Receive HTTP Server Data
This command permits the user to read data from HTTP server in response to a previous
HTTP module request.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#HTTPRCV=<prof_id>,[<maxByte>]
Execution command permits the user to read data from HTTP server in
response to a previous HTTP module request.
The module is notified of these data by the #HTTPRING URC.
The device shall prompt a three character sequence
<less_than><less_than><less_than> (IRA 60, 60, 60) followed by the data.
If reading ends successfully, the response is OK; otherwise an error code
is reported.
Parameters:
Name
Type
Default
Description
<prof_id>
integer
N/A
profile identifier
Value:
0÷2
:
profile identifier
<maxByte>
integer
0
max number of bytes to read at a time
Values:
0
:
means infinite size
64÷1500
:
supported range
if <maxByte> is unspecified, server data will be transferred all in
once.

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals