LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1855 of 1904 2022-03-04
3.35.12. AT#BSCANRSPDATA - BLE Scan Response Data
This command is used to set the BLE scan response data.
AT#BSCANRSPDATA=<Include Device Name>,<Manufacturer
Data>,<Service Data>,<128-bit Service UUID>
Set command is used to set the scan response data for a customized
advertising.
The maximum scan response data length can be 32 bytes. The AT
command parameters represent different elements in scan response
data. While setting the parameter values, make sure the total scan
response data does not exceed 32 bytes.
Parameters:
It specifies the device name to be
included or not in the scan
response data.
The supported parameter value range.
It specifies the manufacturer
specific data to be included in the
scan response data.
Note: Manufacturer specific data
should be provided as HEX string
The supported parameter value range.