3.25.3. AT#DWSENDR - Send Raw Data to IoT Portal
The command is related to sending data to the IoT Portal
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#DWSENDR=<dataLen>
Execution command permits to send raw data to the M2M Service.
Content must be valid JSON.
Parameter:
Name
Type
Default
Description
<dataLen>
integer
N/A
number of bytes to be sent
Value:
1÷1500
:
range of the number of bytes to be sent
Additional info:
<dataLen> - number of bytes to be sent
The module responds to the command with the prompt
<greater_than><space> and waits for the data to send.
When <dataLen> bytes have been sent, operation is automatically
completed.
If data are successfully sent, then the response is OK.
If data sending fails for some reason, an error code is reported.

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals