0 - normal operating mode
1 - alarm mode or normal operating mode with some alarm activity.
AT#WAKE=?
Test command returns OK result code.
The alarm mode is indicated by status ON of hardware pin CTS and
by status ON of pin DSR; the power saving status is indicated by a
CTS - OFF and DSR - OFF status; the normal operating status is
indicated by DSR - ON.
During the alarm mode the device will not make any network scan
and will not register to any network and therefore is not able to dial
or receive any call or SM, the only commands that can be issued to
the MODULE in this state are the #WAKE and #SHDN, every other
command must not be issued during this state.