The module is shutdown(action-5) at temperature above the Extreme up
zone threshold (105 deg).
"#TEMPMON" set command, changes field "actions" to "mitigate" or "none"
to all zones.
The temperature correctly set are saved in a configuration file in the
module file system.
AT#TEMPCFG?
Read command reports the current parameter setting for #TEMPCFG command in
the format:
#TEMPCFG: <etlz_clr>,<etlz>,<etlz_act_in>,<otlz_clr>,<otlz>,<otlz_act_in>,<otnz_c
lr>,
<otnz>,<otnz_act_in>,<otuz_clr>,<otuz>,<otuz_act_in>,<etuz_clr>,<etuz>,<etuz_act
_in>
AT#TEMPCFG=?
Test command reports the supported range values for parameters <x_clr>,<x>,
<x_act_in>, where "x" is substitute for etlz, otlz, otnz, otuz, etuz.
Values are:
#TEMPCFG: (-40-105),(-40-105),(0-5)