LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1162 of 1904 2022-03-04
enables the presentation of the temperature
monitoring URC, whenever the module internal
temperature reaches either operating or extreme
levels.
sum of integers, each representing
the action to be done whenever the
module internal temperature
reaches either operating or
extreme levels.
(01) Activating of thermal mitigation according to
thermal configuration file.
(10) Output pin <GPIO> is tied HIGH when operating
temperature bounds are reached; when the
temperature is back to normal the output pin
<GPIO> is tied LOW. If this <action> is required, it is
mandatory to set the <GPIO> parameter too.
(11) This value contains <action=1> and <action=2>
i.e. activate thermal mitigation and a GPIO
indication. If this <action> is required, it is
mandatory to set the <GPIO> parameter too.
GPIO number. Valid range is any
GPIO pin as described in #GPIO
command. This parameter is
needed and required only if
<action> 2 or 3 is enabled.
threshold level (see Note1)
Values:
Extreme temperature lower bound.