EasyManuals Logo

Telit Wireless Solutions LE910C series At Commands Reference Guide

Telit Wireless Solutions LE910C series
1904 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1250 background imageLoading...
Page #1250 background image
LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1250 of 1904 2022-03-04
Not Subject to NDA
255
:
local host closes only after an escape
sequence (+++)
If successful, command returns a final result code OK. If the
ListenAutoRsp flag has not been set through the command
#SCFGEXT (for the specific <connId>), then, when a TCP connection
request comes on the input port, if the sender is not filtered by
internal firewall (see #FRWL), an URC is received:
+SRING : <connId>
Afterwards we can use #SA to accept the connection or #SH to
refuse it.
If the ListenAutoRsp flag has been set, then, when a TCP
connection request comes on the input port, if the sender is not
filtered by the internal firewall (see #FRWL), the connection is
automatically accepted: the CONNECT indication is given and the
modem goes into online data mode.
If the socket is closed by the network the following URC is
received:
#SKTL: ABORTED
AT#SL?
Read command returns all the actual listening TCP sockets.
AT#SL=?
Test command returns the range of supported values of the parameters.

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals