LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1287 of 1904 2022-03-04
When <mode>=1, the command returns the following last data
counts:
The message format is:
#GDATAVOL: <cid
n
>,<tot
n
>,<sent
n
>,<received
n
>[<CR><LF>
...
#GDATAVOL: <cid
m
>,<tot
m
>,<sent
m
>,<received
m
>[...]]
Each message line shows the data related to the n-th, m-th, and so
on <cid>.
number of bytes either received
or transmitted in the last PS
session for <cid
n
> PDP context;
number of bytes transmitted in
the last PS session for
<cid
n
> PDP context;
number of bytes received in the
last PS session for <cid
n
> PDP
context;
When <mode>=2, the command returns the following total data
counts, since last reset executed by AT#GDATAVOL=0
The message format is: