LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1668 of 1904 2022-03-04
Not Subject to NDA
0÷14400
:
0 is the low delay and 14400 is
the highest delay in seconds
<age_of_location_info>
integer
0
maximum
age of
location
Value:
0÷1966020
:
Value 0 means that stored
location information should
not be used. Value 1966020
indicates the maximum
tolerable age of the stored
location information. The
valid range of interval for
SUPL (Transport protocol) is
[0 - 65535] seconds & [0 -
1966020] seconds for C-plane
(Transport protocol).
<location_type>
integer
0
type of
location
required.
Used only
in case of
C-Plane
Values:
0
:
Current Location
1
:
Current or Last known location
2
:
Invalid Location, indicates that this
parameter shall not be used
<nav_profile>
integer
0
navigation
profile
Values:
0
:
Car navigation profile

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals