LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1700 of 1904 2022-03-04
Not Subject to NDA
- N*1000 milliseconds - 1Hz rate and lower with one second boundaries, in
case <update_rate>=0.
All intervals are rounded down to the nearest supported value if they are
lower than 1000 ms.
Time interval in milliseconds = Round down(<interval> of $GPSSLSR * NHz
interval(milliseconds)).
For example,
AT$GPSNHZ=3
OK
AT$GPSNHZ?
$GPSNHZ: 3
OK
Rounded down to the nearest supported value:
AT$GPSSLSR=2,3,,,,,1 (100 = 100 milliseconds *1)
OK
$GPRMC,045212.00,A,3731.303808,N,12655.778005,E,0.0,0.0,010219,6.1,W,A,V
*5F
$GPRMC,045212.10,A,3731.303808,N,12655.778005,E,0.0,0.0,010219,6.1,W,A,V
*5E
AT$GPSSLSR=2,3,,,,,2 (200 = 100 milliseconds *2)
OK
$GPRMC,045516.00,A,3731.304115,N,12655.783014,E,0.0,0.0,010219,6.1,W,A,V
*5A
$GPRMC,045516.20,A,3731.304055,N,12655.783031,E,0.0,0.0,010219,6.1,W,A,V
*5A
AT$GPSSLSR=2,3,,,,,3 (200 = 100 milliseconds *3)
OK
$GPRMC,045259.00,A,3731.303742,N,12655.781811,E,0.0,0.0,010219,6.1,W,A,V
*5A
$GPRMC,045259.20,A,3731.303731,N,12655.781815,E,0.0,0.0,010219,6.1,W,A,V
*58