LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1041 of 1904 2022-03-04
Not Subject to NDA
0
:
Store file on FS
1
:
Returns the current <size> of the <category> file
<category>
integer
N/A
ACDB file
Values:
0
:
Audio_cal.acdb
1
:
Bluetooth_cal.acdb
2
:
General_cal.acdb
3
:
Global_cal.acdb
4
:
Handset_cal.acdb
5
:
Hdmi_cal.acdb
6
:
Headset_cal.acdb
7
:
Speaker_cal.acdb
<size>
integer
-
Number of bytes to write to the file
LE910Cx Linux:
In <mode> = 0
After command line terminated with <CR>, We see the
intermediate result code CONNECT.
After this prompt, the file type must be in binary format.
If data successfully sent, then the response is OK.
If data sending fails for some reason, an error code reported.
In <mode> = 1
Command returns the current <size> of the <category> file.
#ACDB: <size>