LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 621 of 1904 2022-03-04
Not Subject to NDA
on acknowledge of current received +CDS response in case +CSMS <service>
parameter set to '1'.
<ds>=2:
+CDSI: <mems>,<index>
Unsolicited fields:
Name
Type
Description
<mems>
string
memory storage where the new message is stored: "SM",
"ME".
<index>
integer
location on the memory where SMS is stored.
<alpha>
string
alphanumeric representation of originator/destination
number corresponding to the entry found in MT phonebook;
used character set should be the one selected with
command +CSCS.
<lenght>
integer
PDU length
<PDU>
string
PDU message
<oa>
string
originating address, string type converted in the currently
selected character set (see +CSCS)
<alpha>
string
alphanumeric representation of <oa>; used character set
should be the one selected with command +CSCS.
<scts>
string
arrival time of the message to the SC
<tooa>
integer
type of number <oa>:
129 - number in national format
145 - number in international format (contains the "+")
<fo>
string
first octet of message PDU, see 3GPP TS 03.40/23.040