are the rules to build the AT command
string.
- The string must start with AT or at
chars
- If the string contains the character ",
then it has to be replaced with the 3
characters \22
- The max string length is 96
characters
- If it is an empty string, then the AT
command is erased
Other <paramType> values define the
<param> meaning according to the
type of event. As stated above, for
each event identified by the <label> is
dedicated an Additional info section to
describe the <paramType> values and
the #EVMONI command behavior.
Values:
0
:
indicates that <param> contains the AT
command string to execute when the related
event has occurred.
n
:
define the <param> meaning according to the
event type. Refer to Additional info section.
<param>
string
-
Its meaning depends on the <label>
and <paramType> parameters. Refer
to Addition info section.
Additional info:
<label>=VBATT, battery voltage monitoring.
<paramType> can assume values in the range 0 - 2.
Name
Type
Default
Description