LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1555 of 1904 2022-03-04
Not Subject to NDA
<param>
integer
0
When <paramType>=1, <param> is
the battery voltage threshold to
monitor.
Value:
0÷500
:
1 unit is 10 mV.
<param>
integer
0
When <paramType>=2, <param> is
the time interval starting from the
instant in which the voltage battery
goes below the threshold specified
with <paramType>=1. When the
interval is elapsed and the voltage
battery is below the threshold, the
#EVMONI executes the AT command
configured with <paramType>=0.
Value:
0÷255
:
seconds
<label>=DTR, DTR monitoring.
<paramType> can assume values in the range 0 - 2.
Name
Type
Default
Description
<param>
integer
0
When <paramType>=1, <param> is
the DTR status to monitor.
Values:
0
:
Low
1
:
High
<param>
integer
0
When <paramType>=2, <param> is
the time interval starting when DTR
status has the value specified with
<paramType>=1. When the interval

Table of Contents