EasyManua.ls Logo

Telit Wireless Solutions LE910C series - Page 1558

Telit Wireless Solutions LE910C series
1904 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1558 of 1904 2022-03-04
Not Subject to NDA
Values:
0
:
GPIO status LOW
1
:
GPIO status HIGH
<param>
integer
0
When <paramType>=3, <param> is
the time interval starting when GPIO
pin has the value specified with
<paramType>=2. When the interval
is elapsed and GPIO pin value is
equal to the value previously
specified, the #EVMONI executes
the AT command configured with
<paramType>=0.
Value:
0÷255
:
sec
<label>=ADCH1, ADC High Voltage monitoring.
<paramType> can assume values in the range 0 - 3.
Name
Type
Default
Description
<param>
integer
1
When <paramType>=1, <param> is
the ADC pin number to monitor.
Value:
1÷max
:
max dependes on the hardware.
<param>
integer
0
When <paramType>=2, <param> is
the ADC High voltage threshold to
monitor.
Value:
0÷2000
:
Expressed in mV

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Related product manuals