LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1560 of 1904 2022-03-04
interval is elapsed and the ADC pin
level is below the previously
specified threshold, the #EVMONI
executes the AT command
configured with <paramType>=0.
Does not matter the fluctuation of
the ADC voltage inside the time
interval.
<label>=DTMF1, DTMF2, DTMF3, DTMF4 monitoring on user defined
DTMF string.
<paramType> can assume values in the range 0 - 2.
When <paramType>=1, <param> is
the DTMF string. The single DTMF
characters have to belong to the
range ((0-9),#,*,(AD)); the maximum
number of characters in the string is
15
When <paramType>=2, <param> is
the maximum time interval within
which a DTMF tone must be
detected after the reception of the
previous one in order to be
considered as belonging to the
DTMF string. When the complete
DTMF string is received, the event
has occured and the #EVMONI
executes the AT command
configured with <paramType>=0