LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1561 of 1904 2022-03-04
Not Subject to NDA
500÷5000
:
Expressed in msec
<label>=SMSIN, monitoring on incoming SMS.
<paramType> can assume values in the range 0 - 1.
Name
Type
Default
Description
<param>
string
-
When <paramType>=1, <param>
contains the text string that must be
received in an incoming SMS to
create the event. In this case,
#EVMONI executes the AT command
configured with <paramType>=0. The
maximum number of characters in
the SMS text string is 15.
If no text is specified in<param>
(empty string), each incoming SMS
triggers the event and #EVMONI
executes the AT command configured
with <paramType>=0.
<label>=CONSUME1, CONSUME2, CONSUME3, CONSUME4,
CONSUME5 used to define an action to be used in consume
functionality, see #CONSUMECFG command.
<paramType> can assume only values 0.
When the action identified by the <action_id> parameter of the
#CONSUMECFG command occurs, the #EVMONI executes the AT
command configured with <paramType>=0.
The DTMF string monitoring is available only if the DTMF decode
has been enabled (see #DTMF command)

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals