Waveform generator (Option R&S RTO6-B6)
R&S
®
RT
O6
1034User Manual 1801.6687.02 ─ 05
The file stream should contain the following information in the given order:
●
Bit rate
[double]
●
High level
[double]
●
Mask
[string of 8 characters made up of "X"/"1"/"0"]
●
Number of samples
[UINT32]
●
Data samples
[UINT8] * number of samples
15.2.2  Pattern generator settings
Enable
Enables the waveform generator/ pattern generator and outputs the signal to the con-
nectors.
Remote command: 
WGENerator<m>[:
ENABle] 
on page 2443
PGENerator:ENABle on page 2456
Run mode
Selects the duration for which the signal of the generator will be output after the trigger
event. You can choose between a "Continuous" and "Single period" duration.
Remote command: 
PGENerator:RUNMode on page 2457
Bit rate
Sets the number of transmitted bits per second for the pattern generator.
Remote command: 
PGENerator:BITRate on page 2456
Run single
Generates a single period of the pattern waveform if "Run mode" is set to "Single
period".
Remote command: 
PGENerator:RUNSingle on page 2457
Load pattern file
Opens a dialog for selecting an existing pattern file. It is possible to load .bin or .csv
files, see Chapter 15.2.1, "Content and format of the pattern generator files",
on page 1033.
Remote command: 
PGENerator:FILE:OPEN on page 2456
PGENerator:FILE[:NAME] on page 2456
Setup of the pattern generator