TRIGger<m>:OUT:PLENgth <PulseLength>
Sets the length of the trigger out pulse.
Suffix:
<m>
.
1..3
Irrelevant, omit the suf
fix.
Parameters:
<PulseLength>
Range: 4E-9 to 0.06
Increment: 20E-9
*RST: 100E-9
Default unit: s
Usage: Asynchronous command
TRIGger<m>:OUT:DELay <Delay>
Sets the delay of the first pulse edge to the trigger point.
The setting is not available if a mask test or measurement is running and the on-viola-
tion event is set to trigger out pulse.
Suffix:
<m>
.
1..3
Irrelevant, omit the suf
fix.
Parameters:
<Delay> Range:
800E-9 to 1
Increment: 1E-9
*RST: 800E-9
Default unit: s
Usage: Asynchronous command
24.9.20 Actions on trigger
TRIGger<m>:EVENt:BEEP........................................................................................... 1431
TRIGger<m>:EVENt:
PRINt........................................................................................... 1432
TRIGger<m>:EVENt:WFMSave.....................................................................................1432
TRIGger<m>:EVENt:RUNexec......................................................................................1432
TRIGger<m>:OUT:ACTion............................................................................................ 1433
TRIGger<m>:EVENt:BEEP <Beep>
Generates a beep sound if the command is set to TRIGger.
Suffix:
<m>
.
1..3
The suffix is irrelevant.