Triggers
R&S
®
RTO6
224User Manual 1801.6687.02 ─ 05
Relative hysteresis
Defines a range in divisions around the trigger level. If the signal oscillates inside this
range and crosses the trigger level, no trigger event occurs.
Remote command:
TRIGger<m>:
LEVel<n>:
NOISe:PERDivision on page 1426
TRIGger<m>:LEVel<n>:NOISe:RELative on page 1426
Show trigger lines
Displays the trigger levels and the hysteresis in the diagrams until you disable this
option.
Remote command:
DISPlay:TRIGger:LINes on page 1392
Hysteresis transparency
Defines the transparency of the hysteresis area above or below the trigger level.
Only visible if Show trigger lines is enabled.
Hysteresis
Displays the automatic hysteresis value for "Hysteresis mode" = "Auto".
6.6 Actions on trigger
Access: "Menu" > "Trigger" > "Action" tab
The action settings define what happens when a trigger occurs. All available actions
can be initiated at the same time.
The R&S RTO6 can provide an external trigger signal to synchronize the measure-
ments of other instruments. The trigger out signal is also adjusted and enabled in the
"Action" tab.
Actions on trigger