Remote control commands
R&S
®
RTO6
2346User Manual 1801.6687.02 ─ 05
Query parameters:
<SearchName>
Return values:
<State> OK | UNK | DISPARITY | DISParity | GLITCH | GLITch
OK
There are no errors in the state of the specified symbol.
UNK
An unknown error was detected for the specified symbol.
DISPARITY = DISParity
A disparity error was detected for the specified symbol.
GLITCH = GLIT
ch
A glitch error was detected for the specified symbol.
*RST: OK
Usage: Query only
SEARch:RESult:EBTB:SYMBol<m>:STOP? <SearchName>
Returns the stop time of the specified symbol within the search result.
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<Stop> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
24.17.27 PCIe (option R&S RTO6K72)
● Configuration.......................................................................................................
2346
● Clock data recovery............................................................................................ 2349
● Trigger.................................................................................................................2351
● Decode results.................................................................................................... 2359
● Search settings................................................................................................... 2368
● Search results..................................................................................................... 2380
24.17.27.1 Configuration
In all BUS<m>:PCIE commands, the suffix <m> selects the serial bus.
Protocols