Remote control commands
R&S
®
RTO6
1389User Manual 1801.6687.02 ─ 05
● Width trigger........................................................................................................
1394
● Runt trigger
......................................................................................................... 1396
● Window trigger.................................................................................................... 1398
● Timeout trigger....................................................................................................1400
● Interval trigger..................................................................................................... 1401
● Slew rate trigger..................................................................................................1403
● Setup & Hold.......................................................................................................1405
● State trigger.........................................................................................................1407
● Pattern trigger..................................................................................................... 1408
● Serial pattern trigger............................................................................................1410
● TV/Video trigger.................................................................................................. 1412
● Trigger qualification.............................................................................................1417
● Holdoff.................................................................................................................1420
● Conditioning........................................................................................................ 1424
● Trigger sequence................................................................................................ 1426
● Trigger control.....................................................................................................1429
● Actions on trigger................................................................................................ 1431
● Zone trigger.........................................................................................................1433
● External trigger input...........................................................................................1434
● Acquisition info....................................................................................................1437
24.9.1 Basic trigger settings
TRIGger<m>:SOURce[:SELect].....................................................................................1389
TRIGger<m>:TYPE......................................................................................................1390
TRIGger<m>:LEVel<n>[:VALue].................................................................................... 1391
TRIGger<m>:FINDlevel................................................................................................ 1392
DISPlay:TRIGger:LINes................................................................................................1392
TRIGger<m>:SOURce[:SELect] <SourceDetailed>
Selects the source of the trigger signal.
Suffix:
<m>
.
1..3
1 = A-trigger
, 2 = B-trigger
, 3 = R-trigger
Available values depend on the selected trigger source. For
input channels CHAN1...4, a trigger sequence can be config-
ured.
For all other trigger sources, only suffix 1 is allowed.
Parameters:
<SourceDetailed> CHAN1 | CHANnel1 | CHAN2 | CHANnel2 | CHAN3 |
CHANnel3 |
CHAN4 | CHANnel4 | EXT
ernanalog | SBUS | D0 |
D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9 | D10 | D11 | D12 |
D13 | D14 | D15 | LOGIC | MSOB1 | MSOB2 | MSOB3 |
MSOB4 | Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 |
Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4 | DIFF1 |
DIFF2 | COMMON1 | COMMON2
Trigger