Return values:
<Value> Range: 0 to 255
Increment: 1
*RST: 0
Usage: Query only
24.17.4 SPI (option R&S RTO6-K510)
SPI bus configuration..........................................................................................1708
SPI trigger
........................................................................................................... 1712
SPI decode results..............................................................................................1715
SPI search settings............................................................................................. 1720
SPI search results...............................................................................................1723
24.17.4.1 SPI bus configuration
BUS<m>:SPI:BORDer..................................................................................................1708
BUS<m>:SPI:WSIZe.................................................................................................... 1709
BUS<m>:SPI:SCLK:SOURce........................................................................................1709
BUS<m>:SPI:SSELect:SOURce....................................................................................1709
BUS<m>:SPI:SSELect:POLarity....................................................................................1710
BUS<m>:SPI:MISO:SOURce........................................................................................ 1710
BUS<m>:SPI:MISO:POLarity........................................................................................ 1710
BUS<m>:SPI:MOSI:SOURce........................................................................................ 1711
BUS<m>:SPI:MOSI:POLarity.........................................................................................1711
BUS<m>:SPI:SCLK:THReshold.....................................................................................1711
BUS<m>:SPI:MISO:THReshold.....................................................................................1711
BUS<m>:SPI:MOSI:THReshold.....................................................................................1711
BUS<m>:SPI:SSELect:THReshold.................................................................................1711
BUS<m>:SPI:FRCondition............................................................................................ 1712
BUS<m>:SPI:TIMeout.................................................................................................. 1712
BUS<m>:SPI:BORDer <BitOrder>
Defines if the data of the messages starts with msb (most significant bit) or lsb (least
significant bit).
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<BitOrder> LSBF | MSBF
*RST: MSBF