Most SPI buses have four lines, two data and two control lines:
Clock line to all slaves (SCLK)
Slave Select or Chip Select line (SS or CS)
Master data output, slave data input (MOSI or SDI)
Master data input, slave data output (MISO or SDO)
When the master generates a clock and selects a slave device, data may be transfer-
red in either or both directions simultaneously.
Figure 13-4: Simple configuration of SPI bus
The data bits of a message are grouped by following criteria:
A word contains a number of successive bits. The word length is defined in the pro-
tocol configuration.
A frame contains a number of successive words, at least one word.
13.3.2 SPI configuration
13.3.2.1 SPI configuration settings
Access: [Bus] > "SPI" > "Setup" tab
Make sure that the tab of the correct serial bus is selected.
SPI bus (option R&S RT
O6-K510)