Jitter analysis and clock data recovery
R&S
®
RTO6
1103User Manual 1801.6687.02 ─ 05
Remote command:
ADVJitter<m>:
DCOMposition:
CLENoisecomp on page 2499
ADVJitter<m>:DCOMposition:SELNoisecomp on page 2499
Levels
Selects which levels are considered for the display of the diagrams, rising, falling or
both. This setting is mostly relevant for histograms, tracks and the measurement
results.
Remote command:
ADVJitter<m>:RESult:LEVels on page 2500
18.2.5.5 Bathtub settings
Access: "Analysis" menu > "Advanced Jitter" > "Result" tab > "Bathtub".
Target BER 10
Sets the target bit error rate.
Remote command:
ADVJitter<m>:DCOMposition:
TARBer on page 2500
DDJ bathtub
Enables a bathtub plot, a graph of BER in a log scale versus data-dependent jitter
(DDJ).
Advanced jitter and noise (option R&S RT
O6- K133/K134)