Jitter analysis and clock data recovery
R&S
®
RTO6
1069User Manual 1801.6687.02 ─ 05
See: Chapter 18.2, "Advanced jitter and noise (option R&S R
T
O6- K133/K134)",
on page 1079.
● Jitter measurements (options R&S RTO6-K12/K13)...........................................1069
● Advanced jitter and noise (option R&S RTO6- K133/K134)................................1079
● Clock data recovery.............................................................................................1112
18.1 Jitter measurements (options R&S RTO6-K12/K13)
This chapter describes the measurement setup in the "Jitter" category.
● Jitter measurements............................................................................................1069
● Jitter measurement settings................................................................................1071
● Jitter statistics and histogram..............................................................................1077
● Track of jitter measurement results.....................................................................1078
● Jitter spectrum.....................................................................................................1079
18.1.1 Jitter measurements
The measurement category "Jitter" gathers all measurements which are useful for jitter
analysis. The category contains jitter-specific measurements. In addition, the following
amplitude/time measurements are added to the jitter category, because they are useful
for jitter analysis:
●
Period
●
Frequency
●
Setup time
●
Hold time
●
Setup/Hold ratio
The amplitude/time measurements are described in "Time measurements"
on page 318.
The specific jitter measurements are described in Table 18-1.
Jitter measurements (options R&S RT
O6-K12/K13)