Remote control commands
R&S
®
RTO6
2543User Manual 1801.6687.02 ─ 05
POWer:ONOFf:RESult:TOFF?
POW
er:ONOFf:RESult:
TON?
Returns the result time.
Return values:
<TurnOnTime> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
POWer:ONOFf:TIME <Time>
Sets the time, the start of the measurement of the turn off time is delay with, after the
trigger point.
Parameters:
<Time> Range: 100E-12 to 10000
Increment: 100E-9
*RST: 0.1
Default unit: s
POWer:ONOFf:TYPE <MeasType>
Selects the measurement type.
Parameters:
<MeasT
ype> TON | TOFF
TON -
"Turn on" measurement
TOFF - "Turn off" measurement
*RST: TON
24.23.12 Switching loss
POWer:SWITching:AUTO............................................................................................. 2544
POWer:SWITching:EXECute......................................................................................... 2544
POWer:SWITching:REPort:ADD.................................................................................... 2544
POWer:SWITching:SWIFrequency.................................................................................2544
POWer:SWITching:SWIT.............................................................................................. 2545
POWer:SWITching:COND.............................................................................................2545
POWer:SWITching:NCON.............................................................................................2545
POWer:SWITching:TON................................................................................................2545
POWer:SWITching:TOFF..............................................................................................2545
POWer:SWITching:TOTal..............................................................................................2545
POWer:SWITching:GATE:COND:STARt......................................................................... 2545
POWer:SWITching:GATE:COND:STOP..........................................................................2545
POWer:SWITching:GATE:NCON:STARt......................................................................... 2545
POWer:SWITching:GATE:TOFF:STARt.......................................................................... 2545