13.12.2 MIL-STD-1553 configuration
13.12.2.1 MIL-STD-1553 configuration settings
Access: [Bus] >
"Decode"
tab > "Protocol" = MIL-STD-1553
Access: [Bus] > "MIL-1553" > "Setup" tab
Make sure that the tab of the correct serial bus is selected.
See also: Chapter 13.1.1, "Setup - general settings", on page 485
Source
Sets the source of the selected data line. Waveform 1 of channel signals, math wave-
forms, and reference waveforms can be used.
For triggering on a serial bus, a channel signal is required.
Remote command:
BUS<m>:
MILStd:SOURce on page 1957
Polarity
Selects the wire on which the bus signal is measured : "Normal" or "Inverted". The set-
ting affects the digitization of the signal.