Remote control commands
R&S
®
RTO6
1382User Manual 1801.6687.02 ─ 05
Parameters:
<ScaleCoupling> ON | OFF
*RST: ON
Usage: Asynchronous command
DIFFerential<m>:COMMon:OFFSet <Offset>
DIFFerential<m>:DIFFerential:OFFSet
<Offset>
Set the offset of differential and common mode waveforms.
Vertical settings of P and N output are the vertical settings of the input channels.
Suffix:
<m>
.
1..2
Differential signal
Parameters:
<Of
fset> Offset value
Range: -1 to 1
Increment: 0.01
*RST: 0
Default unit: V
Usage: Asynchronous command
DIFFerential<m>:COMMon:POSition <Position>
DIFFerential<m>:DIFFerential:POSition
<Position>
Set the vertical position of differential and common mode waveforms.
Vertical settings of P and N output are the vertical settings of the input channels.
Suffix:
<m>
.
1..2
Differential signal
Parameters:
<Position> Position value
Range:
-5 to 5
Increment: 0.02
*RST: 0
Default unit: div
Usage: Asynchronous command
24.8.10 Digital filter
CHANnel<m>:DIGFilter:ST
ATe...................................................................................... 1383
CHANnel<m>:DIGFilter:CUToff......................................................................................1383
TRIGger<m>:COUPling................................................................................................1383
TRIGger<m>:RFReject.................................................................................................1384