Chapter 24.3, "Programming examples", on page 1259
Measurement setup............................................................................................
2559
Save and load the deembedding setup.............................................................. 2561
Components........................................................................................................2562
Responses.......................................................................................................... 2568
24.24.1 Measurement setup
DEEMbedding<m>[:STATe]...........................................................................................2559
DEEMbedding<m>:ADD............................................................................................... 2559
DEEMbedding<m>:REMove..........................................................................................2560
DEEMbedding<m>:CCOunt?........................................................................................ 2560
DEEMbedding<m>:BANDwidth..................................................................................... 2560
DEEMbedding<m>:CMPDelay...................................................................................... 2561
DEEMbedding<m>:PRESet.......................................................................................... 2561
DEEMbedding<m>[:STATe] <State>
Activates the deembedding - the correction of parasitic effects of the measurement
setup on the measured signal.
Suffix:
<m>
.
1..4
Selects the channel that is configured for deembedding.
Parameters:
<State> ON | OFF
*RST: OFF
Usage: Asynchronous command
DEEMbedding<m>:ADD <Index>, [<Type>]
Adds a component to the measurement setup.
Suffix:
<m>
.
1..4
Selects the channel that is configured for deembedding.
Setting parameters:
<Index> Defines the place of the component in the measurement path.
The DUT is always the first component (index = 1), the probe or
input is the last component.
<T
ype> PROBe | FIXTure | CABLe | DUT | ADAPter | INPut | OTHer |
R
TZA10 | R
TZA16 | RTZA17 | PP | PC | COPRobes
RTZA10 | RTZA16 | RTZA17
SMA adapters and cable offered by Rohde & Schwarz
PP | PC
Proven probe, proven cable
Deembedding (option R&S RT
O6-K121)