Remote control commands
R&S
®
RTO6
2527User Manual 1801.6687.02 ─ 05
Return values:
<Count>
POWer:REPort:TEST:LSENd? <MeasT
ype>
Query parameters:
<MeasT
ype> QUAL | RUSH | HARM | MODU | DONR | SLEW | SOA | TURN |
SWIT | EFF |
RIPP | TRANS | SPEC
Usage: Query only
24.23.4 Power quality
POWer:
QUALity:AUTO.................................................................................................2527
POWer:QUALity:EXECute.............................................................................................2527
POWer:QUALity:FREQ.................................................................................................2527
POWer:QUALity:FCUS.................................................................................................2528
POWer:QUALity:REPort:ADD........................................................................................2528
POWer:QUALity:RESult:CURRent:CREStfactor?............................................................ 2528
POWer:QUALity:RESult:CURRent:FREQuency?.............................................................2528
POWer:QUALity:RESult:CURRent:PEAK?......................................................................2528
POWer:QUALity:RESult:CURRent:RMS?.......................................................................2528
POWer:QUALity:RESult:POWer:APParent?....................................................................2528
POWer:QUALity:RESult:POWer:PFACtor?..................................................................... 2528
POWer:QUALity:RESult:POWer:PHASe?.......................................................................2528
POWer:QUALity:RESult:POWer:REACtive?....................................................................2528
POWer:QUALity:RESult:POWer:REALpower?................................................................ 2528
POWer:QUALity:RESult:VOLTage:CREStfactor?.............................................................2528
POWer:QUALity:RESult:VOLTage:FREQuency?............................................................. 2528
POWer:QUALity:RESult:VOLTage:PEAK?...................................................................... 2528
POWer:QUALity:RESult:VOLTage:RMS?........................................................................2528
POWer:QUALity:AUTO <Autoscale>
Selects the scaling for the display of the results.
Parameters:
<Autoscale> AUTO | MANUAL
*RST: MANUAL
POWer:QUALity:EXECute
Starts the power quality measurement.
Usage: Event
POWer:QUALity:FREQ <Frequency>
Sets the input frequency of the source signal in Hz.
Power analysis (option R&S RT
O6-K31)