Remote control commands
R&S
®
RTO6
1563User Manual 1801.6687.02 ─ 05
Usage: Asynchronous command
REFLevel<m>:ABSolute:BOTube <V
alue>
Defines an area beneath the low signal level which is still considered to be low level.
Suffix:
<m>
.
Valid suf
fix numbers: 2 to 21, 61 to 68, 108 to 118, 151 to 157,
173 to 179
Source waveform of the measurement, see Chapter 24.4.1,
"Waveform suffix", on page 1279.
Parameters:
<Value>
Usage: Asynchronous command
24.12.15.6 Results
MEASurement<m>:REFLevel:RESult:LOWer?
................................................................1563
MEASurement<m>:REFLevel:RESult:MIDDle?............................................................... 1563
MEASurement<m>:REFLevel:RESult:UPPer?................................................................ 1563
MEASurement<m>:REFLevel:RESult:SIGLow?.............................................................. 1563
MEASurement<m>:REFLevel:RESult:SIGHigh?..............................................................1563
MEASurement<m>:REFLevel:RESult:BINNer?............................................................... 1564
MEASurement<m>:REFLevel:RESult:BOUTer?.............................................................. 1564
MEASurement<m>:REFLevel:RESult:TINNer?............................................................... 1564
MEASurement<m>:REFLevel:RESult:TOUTer?...............................................................1565
MEASurement<m>:REFLevel:RESult:LOWer?
MEASurement<m>:REFLevel:RESult:MIDDle?
MEASurement<m>:REFLevel:RESult:UPPer?
Return the lower, middle, and upper reference level, respectively.
Suffix:
<m>
.
1..10
See "Selection of the measurement group: MEASurement<m>"
on page
1479.
Return values:
<Upper> Range:
-100E+24 to 100E+24
*RST: 0
Usage: Query only
Asynchronous command
MEASurement<m>:REFLevel:RESult:SIGLow?
MEASurement<m>:REFLevel:RESult:SIGHigh?
Return the signal value that represents a low or high level, respectively.
Automatic measurements