Protocol analysis
R&S
®
RTO6
920User Manual 1801.6687.02 ─ 05
●
SEARch:RESult:MPHY:
FRAMe<m>:CELL<n>:DATA? on page 2316
●
SEARch:RESult:MPHY:FRAMe<m>:CELL<n>:TYPE? on page 2316
●
SEARch:RESult:MPHY:FRAMe<m>:CELL<n>:STARt? on page 2316
●
SEARch:RESult:MPHY:FRAMe<m>:CELL<n>:STOP? on page 2317
●
SEARch:RESult:MPHY:FRAMe<m>:CELL<n>:STATe? on page 2317
●
SEARch:RESult:MPHY:FRAMe<m>:DATA? on page 2317
●
SEARch:RESult:MPHY:FRAMe<m>:FTYPe? on page 2318
●
SEARch:RESult:MPHY:FRAMe<m>:STARt? on page 2319
●
SEARch:RESult:MPHY:FRAMe<m>:STATe? on page 2319
●
SEARch:RESult:MPHY:FRAMe<m>:STOP? on page 2320
13.24.5.3 Searching M-PHY
Prerequisite: A serial bus is configured for the M-PHY signal to be decoded and ana-
lyzed.
The search for events is set up in the following way:
1. Press the [Bus] key and selet the "Shortcuts" tab.
2. Tap "Setup search".
3. If the dialog box does not contain a search entry, tap the "Add" icon to create one,
as described in "To create a user-defined search" on page 434.
4. Specify the search criteria according to Chapter 13.24.5.1, "M-PHY search setup",
on page 912.
5. To acquire a waveform, press [Single].
The R&S RTO6 performs an M-PHY decode according to the thresholds and proto-
col settings of the associated serial bus source.
6. To start searching the acquired waveform for specific events, tap "Enable" in the
search setup dialog:
The R&S RTO6 displays the "Search Results" box that lists the detected events.
For information on how to configure the search results presentation and how to navi-
gate the search results, see also "To display search zoom windows" on page 442.
13.24.5.4 SSIC search setup
Access: [Bus] > "Shortcuts" tab > "Setup search"
Search criteria
Use the "Search criteria" dialog to define the search type. If you search for frame con-
tent, define the frame type in which data is to be searched.
M-PHY and USB SSIC (option R&S R
T