EasyManua.ls Logo

R&S RTO6 - 24.12.1 General settings

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTO6
1480User Manual 1801.6687.02 ─ 05
Statistics and long-term measurements..............................................................
1533
Protocol
...............................................................................................................1539
Track and trend...................................................................................................1545
Gating..................................................................................................................1546
Limit check and event actions.............................................................................1549
Reference levels................................................................................................. 1552
24.12.1 General settings
MEASurement<m>[:ENABle].........................................................................................1480
MEASurement<m>:SOURce.........................................................................................1480
MEASurement<m>:FSRC.............................................................................................1482
MEASurement<m>:SSRC.............................................................................................1482
MEASurement<m>:CATegory........................................................................................1482
MEASurement<m>:MAIN..............................................................................................1483
MEASurement<m>:ADDitional.......................................................................................1484
MEASurement<m>:AON...............................................................................................1485
MEASurement<m>:AOFF............................................................................................. 1485
MEASurement<m>[:ENABle] <State>
Switches the indicated measurement on or off.
Suffix:
<m>
.
1..10
See "Selection of the measurement group: MEASurement<m>"
on page
1479.
Parameters:
<State> ON |
OFF
*RST: OFF
Example: See "Simple frequency and amplitude measurement"
on page
1262.
Usage: Asynchronous command
MEASurement<m>:SOURce <SignalSource>, [<SignalSource2>]
Defines the source of the measurement. Availability of sources depends on the
selected category and installed options.
Suffix:
<m>
.
1..10
See
"Selection of the measurement group: MEASurement<m>"
on page 1479.
Automatic measurements

Table of Contents

Other manuals for R&S RTO6