Remote control commands
R&S
®
RTO6
1481User Manual 1801.6687.02 ─ 05
Parameters:
<SignalSource> C1W1 | C1W2 | C1W3 | C2W1 | C2W2 | C2W3 | C3W1 | C3W2 |
C3W3 | C4W1 | C4W2 | C4W3
| M1 | M2 |
M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4 | SBUS1 | SBUS2 | SBUS3 |
SBUS4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9 | D10 |
D11 | D12 | D13 | D14 | D15 | TRK1 | TRK2 | TRK3 | TRK4 |
TRK5 | TRK6 | TRK7 | TRK8 | SG1TL1 | SG1TL2 | SG2TL1 |
SG2TL2 | SG3TL1 | SG3TL2 | SG4TL1 | SG4TL2 | SG5TL1 |
SG5TL2 | SG6TL1 | SG6TL2 | SG7TL1 | SG7TL2 | SG8TL1 |
SG8TL2 | Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 |
Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4 | DIFF1 |
DIFF2 | COMMON1 | COMMON2 | | SRESponse1 | SRTRack1 |
SDTRack1 | TJTRack1 | DJTRack1 | DDJTrack1 | PJTRack1 |
RJTRack1 | SRESponse2 | SRTRack2 | SDTRack2 |
TJTRack2 | DJTRack2 | DDJTrack2 | PJTRack2 | RJTRack2 |
SEYE1 | SEYE2 | TNTRack1 | DNTRack1 | DDNTrack1 |
PNTRack1 | RNOTrack1 | TNTRack2 | DNTRack2 |
DDNTrack2 | PNTRack2 | RNOTrack2 | PJDTrack1 |
PJDTrack2 | PNDTrack1 | PNDTrack2
First source of the measurement, see Chapter 24.4.2, "Wave-
form parameter", on page 1284
<SignalSource2> C1W1 | C1W2 | C1W3 | C2W1 | C2W2 | C2W3 | C3W1 | C3W2 |
C3W3 | C4W1 | C4W2 | C4W3
| M1 | M2 |
M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 |
D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15 | TRK1 | TRK2 |
TRK3 | TRK4 | TRK5 | TRK6 | TRK7 | TRK8 | Z1V1 | Z1V2 |
Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 | Z2V1 | Z2V2 | Z2V3 |
Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4 | DIFF1 | DIFF2 | COMMON1 |
COMMON2 | | SRESponse1 | SRTRack1 | SDTRack1 |
TJTRack1 | DJTRack1 | DDJTrack1 | PJTRack1 | RJTRack1 |
SRESponse2 | SRTRack2 | SDTRack2 | TJTRack2 |
DJTRack2 | DDJTrack2 | PJTRack2 | RJTRack2 | SEYE1 |
SEYE2 | TNTRack1 | DNTRack1 | DDNTrack1 | PNTRack1 |
RNOTrack1 | TNTRack2 | DNTRack2 | DDNTrack2 |
PNTRack2 | RNOTrack2 | PJDTrack1 | PJDTrack2 |
PNDTrack1 | PNDTrack2
Second measurement source. The 2nd source is required for
amplitude/time measurements that are performed on two wave-
forms (e.g. delay, phase).
Digital channels are only available if <SignalSource> is a digital
channel.
Step response, advanced jitter track components and synthetic
eye sources are available for amplitude/time measurements
only.
*RST: C1W1,C2W1
Example: See "Simple frequency and amplitude measurement"
on page
1262.