Remote control commands
R&S
®
RTO6
1433User Manual 1801.6687.02 ─ 05
Parameters:
<RunExecutable> NOACtion | TRIGger
*RST: NOACtion
Usage: Asynchronous command
TRIGger<m>:OUT:ACTion <StateAction>
Enables/disbales the trigger out signal that is provided to the [T
rigger Out] connector
on the rear panel when a trigger occurs.
Suffix:
<m>
.
1..3
Parameters:
<StateAction> NOACtion | TRIGger
*RST: NOACtion
Usage: Asynchronous command
24.9.21 Zone trigger
TRIGger<m>:ZONE:EXPRession[:DEFine] <LogiExpr>
Defines the zone trigger.
Suffix:
<m>
.
1..3
The suffix is irrelevant.
Parameters:
<LogiExpr>
String with the logical expression
Example: Prerequisite: mask tests MT1 and MT2 are defined, and also
Zone1.
TRIGger:
ZONE:EXPRession
'MT1 and MT2 and Zone1'
TRIGger:ZONE:EXPRession?
<-- MT1 and MT2 and Zone1
Usage: Asynchronous command
Firmware/software: FW 3.20
SWTRigger:HISTory <ApplyZnTrigHistory>
Applies the zone trigger condition to the acquisitions in the history memory during his-
tory replay
.
See: "Apply zone trigger to history" on page 235.
Parameters:
<ApplyZnTrigHistory> ON | OFF
*RST: OFF