Remote control commands
R&S
®
RTO6
1384User Manual 1801.6687.02 ─ 05
Usage: Asynchronous command
TRIGger<m>:RFReject <Bandwidth>
Suffix:
<m>
.
1..3
Irrelevant, omit the suf
fix.
Parameters:
<Bandwidth>
Range: 100E+3 to 2E+9
Increment: 1000
*RST: 1E+6
Default unit: Hz
Usage: Asynchronous command
24.8.11 Skew
CHANnel<m>:SKEW:MANual.......................................................................................
1384
CHANnel<m>:SKEW:TIME........................................................................................... 1384
PROBe<m>:SKEState..................................................................................................1385
CHANnel<m>:SKEW:EXTended.................................................................................... 1385
CHANnel<m>:SKEW:MANual <ManualCompens>
If enabled, the skew offset value (CHANnel<m>:SKEW:TIME) is used for compensa-
tion. This improves horizontal and trigger accuracy.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<ManualCompens> ON | OFF
*RST: ON
Usage: Asynchronous command
CHANnel<m>:SKEW:TIME <Offset>
Sets an delay value, that is known from the circuit specifics but cannot be compensa-
ted by the instrument automatically
. It affects only the selected input channel.
Suffix:
<m>
.
1..4
Selects the input channel.
Acquisition and setup