Remote control commands
R&S
®
RTO6
2539User Manual 1801.6687.02 ─ 05
POWer:SLEWrate:RESult:STDDev? <MeasT
ype>
POW
er:SLEWrate:RESult:WFMCount? <MeasType>
Return the specified statistic result of the specified measurement type.
[:ACTual]: current measurement result
AVG: average of the long-term measurement results
EVTCount: number of measurement results in the long-term measurement
NPEak: negative peak value of the long-term measurement results
PPEak: positive peak value of the long-term measurement results
RMS: RMS value of the long-term measurement results
STDDev: standard deviation of the long-term measurement results
Query parameters:
<MeasType> MIN | MAX
Usage: Query only
24.23.10 S.O.A
POW
er:SOA:
EXECute..................................................................................................2539
POWer:SOA:LINear:ADD..............................................................................................2539
POWer:SOA:LOGarithmic:ADD..................................................................................... 2539
POWer:SOA:LINear:COUNt?........................................................................................ 2540
POWer:SOA:LOGarithmic:COUNt?................................................................................2540
POWer:SOA:LINear:REMove........................................................................................2540
POWer:SOA:LOGarithmic:REMove................................................................................2540
POWer:SOA:LINear:INSert........................................................................................... 2540
POWer:SOA:LOGarithmic:INSert...................................................................................2540
POWer:SOA:LINear:POINt<m>:CURRent...................................................................... 2540
POWer:SOA:LOGarithmic:POINt<m>:CURRent..............................................................2540
POWer:SOA:LINear:POINt<m>:VOLTage.......................................................................2540
POWer:SOA:LOGarithmic:POINt<m>:VOLTage...............................................................2540
POWer:SOA:MASK......................................................................................................2541
POWer:SOA:REPort:ADD.............................................................................................2541
POWer:SOA:SCALe.....................................................................................................2541
POWer:SOA:SWITch....................................................................................................2541
POWer:SOA:EXECute
Starts the safe operating area measurement.
Usage: Event
POWer:SOA:LINear:ADD
POWer:SOA:LOGarithmic:ADD
Adds a point.
Usage: Event
Power analysis (option R&S RT
O6-K31)

Table of Contents