Remote control commands
R&S
®
RTO6
1909User Manual 1801.6687.02 ─ 05
Parameters:
<CRCError> ON | OFF
*RST: ON
TRIGger<m>:SENT:IRFLength <IrregularFrmLen>
Triggers on frame length errors in transmission sequences when pause pulse for con-
stant frame length is set, see
BUS<m>:SENT:PPULse PPFL.
An error occurs when the total length of the transmission sequence (including pause
pulse) does not match the frame length setting, see BUS<m>:SENT:PPFLength
on page 1902.
To trigger on an error event, select the correspondig trigger type with TRIG
ger<m>:SENT:TYPE ERRC.
Parameters:
<IrregularFrmLen> ON | OFF
*RST: OFF
24.17.11.3 Decode results
To load and acivate a label list, use:
BUS<m>:
NEWList on page 1672
BUS<m>:SYMBols on page 1672
BUS<m>:SENT:FCOunt?..............................................................................................1909
BUS<m>:SENT:FRAMe<n>:STATus?.............................................................................1910
BUS<m>:SENT:FRAMe<n>:STARt?.............................................................................. 1910
BUS<m>:SENT:FRAMe<n>:STOP?............................................................................... 1910
BUS<m>:SENT:FRAMe<n>:CSValue?........................................................................... 1911
BUS<m>:SENT:FRAMe<n>:DATA?................................................................................1911
BUS<m>:SENT:FRAMe<n>:IDTYpe?............................................................................. 1911
BUS<m>:SENT:FRAMe<n>:IDValue?............................................................................ 1912
BUS<m>:SENT:FRAMe<n>:NIBBle<o>:STATe?.............................................................. 1912
BUS<m>:SENT:FRAMe<n>:NIBBle<o>:VALue?..............................................................1913
BUS<m>:SENT:FRAMe<n>:PAPTicks?..........................................................................1913
BUS<m>:SENT:FRAMe<n>:SCOM?..............................................................................1913
BUS<m>:SENT:FRAMe<n>:SDATa?..............................................................................1914
BUS<m>:SENT:FRAMe<n>:SDEXport?......................................................................... 1914
BUS<m>:SENT:FRAMe<n>:SYMBol?............................................................................1914
BUS<m>:SENT:FRAMe<n>:SYNCduration?...................................................................1915
BUS<m>:SENT:FRAMe<n>:TYPE?............................................................................... 1915
BUS<m>:SENT:RDSL.................................................................................................. 1916
BUS<m>:SENT:FRAMe<n>:BITRate?............................................................................1916
BUS<m>:SENT:FCOunt?
Returns the number of decoded frames of the acquisition.