Remote control commands
R&S
®
RTO6
1865User Manual 1801.6687.02 ─ 05
Return values:
<ByteState> OK | STERror | SPERror | PRERror | UVAL | NOEXists |
INSuf
ficient
*RST
: OK
Usage: Query only
SEARch:RESult:LIN:FRAMe<m>:BYTE<n>:VALue? <SearchName>
Suffix:
<m>
.
*
<n> *
Query parameters:
<SearchName>
Return values:
<ByteValue> Range: 0 to 255
Increment: 1
*RST: 0
Usage: Query only
24.17.10 Flexray (option R&S RTO6-K520)
● Configuration.......................................................................................................1865
● T
rigger.................................................................................................................1870
● Decode results.................................................................................................... 1878
● Search settings................................................................................................... 1884
● Search results..................................................................................................... 1893
24.17.10.1 Configuration
BUS<m>:FLXRay:SRCType..........................................................................................1865
BUS<m>:FLXRay:SOURce<n>..................................................................................... 1866
BUS<m>:FLXRay:THReshold<n>..................................................................................1867
BUS<m>:FLXRay:THENable.........................................................................................1867
BUS<m>:FLXRay:THData............................................................................................ 1867
BUS<m>:FLXRay:PRSingle.......................................................................................... 1867
BUS<m>:FLXRay:PRDiff.............................................................................................. 1868
BUS<m>:FLXRay:PRLogic........................................................................................... 1868
BUS<m>:FLXRay:POLarity...........................................................................................1869
BUS<m>:FLXRay:BITRate............................................................................................1869
BUS<m>:FLXRay:CHTYpe........................................................................................... 1869
BUS<m>:FLXRay:SEHB...............................................................................................1869
BUS<m>:FLXRay:SRCType <SourceType>
Sets the type of measurement.
Protocols