Remote control commands
R&S
®
RTO6
2578User Manual 1801.6687.02 ─ 05
Return values:
<StatusBitNumber> Bit number, see "ST
A
Tus:QUEStionable:MASK register"
on page 1252.
Range: 0 to 7
Increment: 1
*RST: 0
Example:
:MTESt:SBITnumber? 'MT1'
<--0
:MTESt:SBITnumber? 'MT2'
<--1
:MTESt:SBITnumber? 'MT3'
<--2
Usage: Query only
Asynchronous command
24.27 Remote trace
The commands in this section configure tracing of the remote control interface and of
events. They also configure the display of the SCPI remote trace.
Before you start tracing, configure all settings as desired. Modifying settings while trac-
ing is active may result in loss of already traced data. Useful exception: Selecting a
new target file while tracing is allowed. For start mode EXPLicit a restart of the
instrument resets the settings to the documented default values.
If you want to start tracing already during startup of the instrument, configure all set-
tings (including start mode AUTO). Then restart your instrument. T
racing will be started
automatically during the restart, using the already configured settings.
If you use an XML file as trace file, ensure that tracing is stopped properly. If tracing is
aborted instead of stopped, for example by shutting down the instrument for stop mode
EXPLicit, the XML file will be invalid, because some tags are not closed.
When the maximum file size is reached (except for stop mode BUFFerfull) or if trac-
ing is started with an already existing trace file, a backup of the trace file is created and
the file itself is reset and overwritten. When the file is full for the second time or when
tracing is started the next time, the first backup file is lost because it is overwritten by
the next backup. In order to prevent loss of data, set a suf
ficient file size, select an
appropriate stop mode and archive/copy completed trace files if you want to keep
them.
24.27.1 Standard commands
TRACe:REMote:MODE:FILE:NAME.............................................................................. 2579
TRACe:REMote:MODE:FILE:FORMat............................................................................2579
TRACe:REMote:MODE:FILE:SIZE.................................................................................2579
TRACe:REMote:MODE:FILE:STARtmode...................................................................... 2579
Remote trace

Table of Contents

Other manuals for R&S RTO6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S RTO6 and is the answer not in the manual?

R&S RTO6 Specifications

General IconGeneral
BandwidthUp to 6 GHz
Sample RateUp to 20 Gsample/s
Memory DepthUp to 2 Gsample
ChannelsUp to 4
Vertical Sensitivity1 mV/div to 10 V/div
Vertical ResolutionUp to 16 bit
Trigger ModesEdge, Pulse
InterfaceLAN, USB, GPIB
Input Impedance50 Ω, 1 MΩ

Related product manuals